Apr 10, 2015 at 18:22 comment added Markus W Mahlberg Please note that running a config server and a data bearing node in one instance is discouraged and that shutting down a config server prevents chunk splits and migrations, which might lead to the dreaded, non-movable jumbo chunks.
Mar 16, 2015 at 13:36 vote accept BAE
Mar 16, 2015 at 13:34 comment added Stennie Yes, you can do this. As noted, if you want to maintain availability in your replica set the normal rules for election apply (i.e. have a majority of nodes available).
Mar 16, 2015 at 13:32 comment added BAE Can I show down one config server and one data server in the replication set at the same time?
Mar 16, 2015 at 0:25 history answered Stennie CC BY-SA 3.0