0

I have an issue with our logical replication which is still on catchup state. It would read several lsn then got stuck on a particular lsn (EA/738D4DA8 both on sent_lsn and write_lsn) then reset again. I read on the logs and found that it has a written log 'terminating walsender process due to replication timeout' How can i resolve this issue? I'm using Postgresql 12 under Windows Server 2019

2
  • 1
    Well, obvious: increase wal_sender_timeout on the primary. Commented Nov 1, 2023 at 17:00
  • Thanks @LaurenzAlbe I increased the sender time out (i also adjust the receiver timeout as well) and now the state changes to streaming Commented Nov 2, 2023 at 21:18

1 Answer 1

0

If your WAL sender times out, the usual solution is to increase wal_sender_timeout on the sending server. You can set the parameter to 0 to disable the timeout mechanism at all.